Full Conformity Assessment is an assessment of the level of compliance of a medical device to the requirements specific to the device as well as to the requirements specified by the Medical Device Authority (MDA) of Malaysia prior to placement of the device in the Malaysian market.
Full Conformity Assessment is carried out for medical devices that are intended to be registered with the Malaysian Medical Device Authority by Local Manufacturers of those devices or by the Local Authorised Representative of the foreign manufacturer of those devices. Registration of medical devices with MDA is done online via the Medical Device Centralised Online Application System (MeDC@St).
The Full Conformity Assessment is a very comprehensive method of assessment of a medical device equivalent to a CE mark assessment. MDA approved conformity assessment of medical devices can only be carried out by Conformity Assessment Bodies (CABs) that have been approved by MDA as per Section 10 of the Malaysia Medical Device Act 2012 (Act 737).
Prior to engaging KGS to carry out Product Verification for a medical device:
For a device to be eligible to proceed for Full Conformity Assessment, the following criteria shall be satisfied:
Class A medical devices are exempted from conformity assessment procedures as per the Medical Device (Exemption) Order 2016, hence, can be registered with by MDA directly via the Medical Device Centralised Online Application System (MeDC@St).
Full conformity Assessment in Malaysia is similar to CE certification or US FDA premarket approval application. No predicate device or prior approval can be used as a leverage for this approval or to follow a simplified registration process. In a Full Conformity Assessment, a thorough scientific and regulatory review is conducted to evaluate the safety and effectiveness of medical devices, regardless of risk classification. The following will be assessed comprehensively:
Consideration will be given to any relevant existing certification and, if not satisfied, KGS may carry out an on-site audit of the manufacturer’s facility. Criteria for acceptance of existing certification shall include the following:
To ensure a PMS is established, maintained and implemented by the establishment. The following processes shall be documented, maintained and implemented by the establishment:
A complete Common Submission Dossier Template (CSDT) must be established by the manufacturer. No abridged version will be accepted. Each and every test report and clinical evaluation reports must be made available and submitted when requested, for thorough evaluation. The adequacy of the documented evidence is determined in support of the manufacturer’s declaration of conformity to the EPSP through a review of the CSDT and technical documentation.
Medical Devices manufacturers shall attest that its medical device complies fully with all applicable Essential Principles for Safety and Performance (EPSP) and other requirements of Act 737 and the subsidiary regulations under it, documented in a written ‘Declaration of Conformity’ (DOC).